The ultrasonic water meter is a high-accuracy electronic flow meter leveraging the ultrasonic time-of-flight principle. It determines flow velocity by measuring the propagation time disparity of ultrasonic waves in the fluid. Contrasting with conventional mechanical water meters, its notable advantages include: absence of moving mechanical components, broad turndown ratio, negligible pressure drop, superior precision, and extended operational life. It is particularly well-suited for intelligent water management systems, industrial metering applications, and district-level leakage monitoring.
Alta precisione: ±1% to ±2% error, better than mechanical meters (±2% to ±5%).
Nessuna parte in movimento: Wear-resistant, lifespan >15 years.
Ampia rapporto di ritorno (da 100: 1 a 400: 1): Measures tiny (e.g., drips) and large flows accurately.
Zero perdita di pressione: Straight-through design doesn’t affect pipeline pressure.
Funzionalità intelligenti: Remote reading, leak monitoring, cloud data management.
Specifiche tecniche chiave
Parametri di base
Parametro | DN15-DN40 (foro piccolo) | Dn50-dn200 (medium {{url_placeholder_0}} fore) | Osservazioni |
Diametro nominale (DN) | 15 ~ 40 mm | 50 ~ 200 mm | Flange {{url_placeholder_0}} connessione
|
Principio di misurazione | Tempo di volo ultrasonico | Tempo di volo ultrasonico | Nessuna girante meccanica |
Rapporto di ritorno (Q₃/Q₁) | 160: 1 ~ 250: 1 | 160: 1 ~ 400: 1 | (Metri meccanici: in genere 80: 1) |
Classe di precisione | Classe 2 | Classe 2 | ± 2% errore |
Temperatura operativa | 0,1-50 ° C (acqua fredda) | 0,1-90 ° C (opzione di acqua calda) | Modelli ad alto tempo personalizzabile
|
Pressione operativa | ≤1,6 MPa | ≤1,6 MPa | Rating di pressione più elevate disponibili (personalizzabile) |
Perdita di pressione | ≤0,15 MPa | ≤0,05 MPa | Caduta a bassa pressione |
Valutazione della protezione dell'ingresso (IP) | IP68 | IP68 | Installazione sommergibile
|
Struttura del prodotto e principio di lavoro