water meter-Shandong Chenshuo

Ultrasonic Water Meter-DN32

The ultrasonic water meter is a high-accuracy electronic flow meter leveraging the ultrasonic time-of-flight principle. It determines flow velocity by measuring the propagation time disparity of ultrasonic waves in the fluid. Contrasting with conventional mechanical water meters, its notable advantages include: absence of moving mechanical components, broad turndown ratio, negligible pressure drop, superior precision, and extended operational life. It is particularly well-suited for intelligent water management systems, industrial metering applications, and district-level leakage monitoring.

Сообщение Контакт
ПРЕИМУЩЕСТВО

Высокая точность: ±1% to ±2% error, better than mechanical meters (±2% to ±5%).

Нет движущихся частей: Wear-resistant, lifespan >15 years.

Широкий коэффициент обновления (от 100: от 1 до 400: 1): Measures tiny (e.g., drips) and large flows accurately.

Нулевая потеря давления: Straight-through design doesn’t affect pipeline pressure.

Умные функции: Remote reading, leak monitoring, cloud data management.

Ключевые технические характеристики

Основные параметры

Параметр DN15-DN40 (маленькое отверстие) Dn50-dn200 (medium {{url_placeholder_0}} bore) Замечания
Номинальный диаметр (DN) 15 ~ 40 мм 50 ~ 200 мм Flange {{url_placeholder_0}} соединение

 

Принцип измерения Ультразвуковое время полета Ультразвуковое время полета Нет механического рабочего колеса
Коэффициент переворота (Q₃/Q₁) 160: 1 ~ 250: 1 160: 1 ~ 400: 1 (Механические счетчики: обычно 80: 1)
Класс точности Класс 2 Класс 2 ± 2% ошибка
Рабочая температура 0,1-50 ° C (холодная вода) 0,1-90 ° C (вариант горячей воды) Модели с высокой температурой настраиваемые

 

Эксплуатационное давление ≤1,6 МПа ≤1,6 МПа Доступны более высокие рейтинги давления (настраиваемый)
Потеря давления ≤0,15 МПа ≤0,05 МПа Низкое падение давления
Рейтинг защиты от входа (IP) IP68 IP68 Погружаемая установка

 

 

Структура продукта и принцип работы

(1) Structural Elements

  • Ultrasonic Transducers: One or multiple transducer pairs for emitting and receiving ultrasonic waves.
  • Flow Measurement Tube: Unobstructed straight-through design (negligible pressure drop).
  • Electronics Module: Performs signal processing, flow computation, data storage, and communication.
  • Display Unit: LCD screen displays flow rate, cumulative usage, alarm messages, etc.

(2) Operational Principle

Measures the time delay (ΔT) of ultrasonic wave transmission in downstream and upstream paths, then computes flow velocity and volume using pipe cross-sectional area:
Скорость потока q = k × (t₁⁻₁⁻ - t₂⁻₂⁻) × a
(K = calibration factor; A = pipe cross-sectional area)

Приложения

  • Intelligent Water Management Systems: DMA (District Metering Area) division, leak detection, and non-revenue water management.
  • Industrial Water Recirculation: Precision flow measurement in chemical, power, and metallurgical sectors.
  • HVAC Systems: Energy metering for chilled/hot water in air conditioning setups.
  • Agricultural Irrigation: High-flow measurement of water with impurities (requires anti-clogging features).